Synchronous PM Motor and Drive Packages - IES2

PM MOTOR WITH NDE INTEGRATED DRIVE - IES2

  • Maximum integration for axial fans
  • PAD mounting to optimize airflow
  • Super Premium Efficiency IE5


TECHNICAL DATA

Motor Type

HPAX 90 1000 23 1.1 kW - 1000 rpm | Drive three-phase - 380-480V

PERFORMANCE DATA

Package Type Rated Speed rpm Rated Power kW Rated Power HP Rated Torque Nm Peak Torque Nm Rated Current Arms Voltage Constant Vs Torque Constant Nm/A Motor Efficiency IE code Motor Efficiency η % Drive Efficiency IE code HPI Efficiency IE code HPI Efficiency η %
HPAX 90 1000 23 1000 1.1 1.5 10.5 15.8 2.3 2.6 4.50 IE5 85.6 IE2 IES2 84.3

Mechanical Data

Design ALUMINIUM
Degree of protection IP 55
Bearings DE 6206 2Z
Bearings NDE 6304 2Z
Lubrication grease low & high temperature grease
Regreasing device permanent lubrication
Cooling IC 411
Vibration Level A (normal)

Electrical Data

Supply Voltage400V - 50Hz
Duty typeS1
Insulation classF
Direction of rotationbidirectional
Ambient temperature-15°C / +40 °C
Altitude1000 m.a.s.l.

Drive Data

Supply Voltagethree-phase
Drive Voltage380-480V
Safety Function-
Drive Torquevariable
FieldbusCANopen; Modbus RTU

 

Inputs2 Digital; 2 Analog
Outputs2 Digital; 2 Analog
Degree of ProtectionIP 55

DIMENSIONS

  • B30
IMHBCEBBLL1ABADJJK
B30909061501143103902499206M12
PRODUCT DOCUMENTATIONSPRODUCT CERTIFICATIONS